AHI Carrier. Системы кондиционирования для зданий и сооружений

Плата тревожных входов LNL-1100

The Lenel® Input Control Module (ICM) provides the access control system with high-speed acknowledgment of critical alarm points in monitored areas. The ICM communicates directly with the Intelligent System Controller (ISC) either by 2-wire or 4-wire RS-485 communication. The ICM has 16 configurable input control points and 2 output control relays. It supports normally open, normally closed, supervised and non-supervised circuits.

The input circuits are scanned using an analog-to-digital converter. The digitized input status signal is software-monitored and controlled, so that each input point can be programmed as a supervised or non-supervised alarm point. The output relays can also be configured for fail-safe or fail-secure operation. Each relay supports the “On,” “Off,” and “Pulse” Lenel OnGuard® software commands.

Lenel
Производитель: Lenel
Особенности
Питание и аксессуары
Технические характеристики
  • Grade B, A, and AA line supervision
  • 12 or 24 VDC input power
  • 16 programmable supervised or non-supervised contacts
  • 2 Form-C 5 A, 28 VDC contacts for load switching
  • 2 dedicated inputs for tamper and power failure status
  • On-board termination jumpers
  • DIP switch-selectable addressing
  • Elevator control, support for 128 floors
  • Status LED for host communication and heartbeat
  • Variable resistor values for line supervision
  • Downloadable firmware

LNL-AL400ULX Lenel UL Listed 4A, 110VAC Power Supply – 12VDC 4A output, 115VAC input, continuous supply current with enclosure (15.5” x 12.5” x 4.5”), lock, tamper switch, UPS capable (Battery Optional) UL & CUL Approved

LNL-AL600ULX-4CB6 Lenel UL Listed Power Supply – 12VDC 6A output, 115VAC (1.6 amps) input, continuous supply current with enclosure (24” x 18” x 4.5”), lock, tamper switch, power distribution module, UPS capable (Battery Optional) UL & CUL Approved

ABT-12 Battery Kit - 12VDC, 12 AH battery (PS-12120)

Название характеристики Значение
Primary Power 12 to 24Vdc ±10%, 350mA maximum
12Vdc @ 300mA nominal, 12.27 BTUs
24Vdc @ 220mA nominal, 18.00 BTUs
Outputs 2 outputs, Form-C, 5A @ 28Vdc, resistive
Inputs 16 unsupervised/supervised, standard EOL: 1k/1k ohm, 1%, 1/4 watt
2 unsupervised, dedicated for cabinet tamper and UPS fault monitoring
Mechancial Dimension: 6” (152mm)W x 8” (203mm)L x 1” (25.4mm)H
Weight: 9 oz. (250 g) nominal
Environmental Temperature Operating: 32°F to 158°F (0°C to +70°C)
Storage: -67°F to 185°F (-55°C to +85°C)
Humidity 0% to 95% RHNC
Compliance Approvals FCC Part 15, CE, RoHS, UL 294, UL 1076, ULC CSA-C22.2, CAN/ULC-S319-05, cUL/ORD-C1076